How to wire a zone valve on a boiler - Each zone valve needs a supply line from the transformer, and a control wire from the thermostat. This allows each zone valve to operate independently, but BOTH have to be wired in parallel from the "end switch" to the boiler's "control circuit", gas valve or circulator, depending on whether it is a constant temperature or "on demand" system.

 
There is an end switch connected between terminal #2 & #3 of the zone valve operator. To activate the boiler control we run another wire from #2 terminal to one of the T terminal of the boiler control. We run another wire from the #3 terminal of the zone valve to the other T or TV terminal of the boiler control.. Gas prices in victorville ca

A 3-way mixing valve, built-in to achieve the low-temperature level of the under floor heating circuit, is controlled by an accessory kit for a heating circuit with a mixing valve. IMPORTANT. System separation is required of underfloor heating systems employing non-oxygen diffusion barrier tubing. gas valve, igniter and blower. When a room thermostat calls for heat, the IBC starts the system circulator and blower. The IBC runs the blower to purge the boiler flue passages, then turns on the igniter and lets it warm up. After igniter warm-up, the IBC opens the gas valve, turns the igniter off, and checks for flame.Vitodens with Zone Valves. Allow the Vitodens to control your system pump it works with constant circ and shuts off on WWSD. Sensor should be inside the box. Make sure you follow the Sart and service guide. Follw each one and the system will purr like a kitten and not a lion. I would recommend going to Viessmann academy schools. They are the best.I am installing new zone valves onto this boiler. First I have tben cut and solder the zone valves. Next I need to wire the zone valves. I need a 24 power an...Having squirrels in your backyard can be fun to watch, but it can also cause damage to your property. Squirrels can dig holes in your lawn, chew on wires and wood, and even eat the...6 with Priority. 120/60/1 VAC, 3A 24 VA per Zone 121⁄4" 8". 40 VA per Transformer. 3". The pump end switches are rated 1⁄6 hp, 5 amps at 120 VAC. The main and priority end switch connections are rated 24 VAC, 1 amp. All thermostat and zone valve connections supply a 24 VAC class 2 output.Options. If that's a spring return (or wax) normally closed valve, the power has to stay on as long as it is to be kept open. If it's a power open, power close valve, then a simple thermostat simply won't work. You will have to have a relay to operate the valve. Relay is operated from the thermostat.See full list on inspectapedia.com Taco Comfort Solutions engineers and manufactures high efficiency indoor heating, cooling, and air quality comfort systems. Purchase Taco products at Supplie...White Rodgers zone valve questions. I just bought a home with a gas boiler with 3 zone valves. They are 1311-102 so they are a 3 wire power close/open valve. Meaning most thermostats are not compatible as they can't signal the valve to close. So, I bought a 2 wire 1361-102 valve and installed that on the my main floor valve.The Chevrolet 5.7-liter (350-cubic-inch) engine employs an overhead valve design that requires occasional maintenance. Adjusting the clearance between the valve stem and rocker arm...I have a radiant floor heat system with a boiler and three zone valves. There are 24V simple honeywell thermostats. The thermostats are wired into the correct pipe zone and valve. ... There are the four wire zone valves (two red and two yellow). One set of red are wired together and to a +'ve on 24V transformer. The other set of red are wired ...Using the high efficiency boiler piping charts in the U.S. Boiler Heating Helper, size the system manifold accordingly. For example, if the condensing boiler is 150K, the boiler piping size will be 1". To get 150K to the house at a 20°F, the system piping would have to be 1-1/4". If piping with closely spaced tees, the tees would have to ...In a zoned system, multiple thermostats control one heating system that selectively distributes heat to different parts of the home. For example, when one zone needs heating, that zone’s valves open, guiding the hot water to the radiators or in-floor pipes in that area of the home. When both zone valves aren’t calling for heat, the boiler ...I've converted the house into a 3 zone system using Taco zone valves and a Taco zone valve controller, still using a single circ pump. Previously, the wiring was much simpler. The thermostat connected directly to the boilers control module and the circ pump did as well. Now that I've introduced the zone valve controller and wired ...My initial plan was to simply remove the old programmer and identify and remove the thermostat wiring and fit the Hive Thermostat Hot Water programmer to the original backplate. However, the cable from the thermostat terminates in a junction box. The cable has a Red, Black and Earth. It appears to connect to the motorised 2 port valve.White Rodgers 1311-102 - 3/4" Sweat Zone Valve (Three Wire)- 3/4" Zone Valve (Three Wire) Features 15 PSI Maximum Differential Across Valve 240 Degrees F Maximum Water Temperature 24 VAC 60Hz 50 PSI Maximum System Pressure ... Boiler Room; Plumbing Supplies; Air Conditioning; Video Library; Project Calculators; Find Parts For Your Unit; Hover ...The old owner have installed 4 Honeywell V8043E1012 zone valves to a Hydro therm HC 165 gas boiler. For some unknown reason he had all 4 zone valves connected to only one thermostat controlling the whole house. I want to wire them properly having a separate thermostat for each zone. The wiring the previous owner did is a nightmare.In this video we do an overview of a basic and very common installation of a Closed Loop Electric Boiler system configured directly to a single zone.On this service call we created a new 4th zone of heating on a hydronic system by adding a Honeywell 4 wire zone valve. In this video I explain and show how ...Steam has mainly been a gaming marketplace for PC games over the years, but Valve appears to be doubling down on the platform’s social aspects with its newly launched Steam Chat me...Country. 17 Dec 2018. #9. Gotcha. The individual zone ufh pumps do allow flow even when they’re not running effectively allowing a bit of flow when the boiler pump is powering the radiators. The zone valves were more intended to stop the radiators heating unnecessarily when the ufh was working harder and longer.Boilers - Home Heating Steam and Hot Water Systems - Boiler, tstat, Zone Valve - Wiring - Hello, I've got what seems like some crazy wiring for my tstats/aquastat, zone valves, and boiler. I'm stumped trying to figure out how, when I my tstats call for heat, that anything is communicated to my boiler. Everything isThe taco zone I have. Has terminals marked 24v- (c) & (w/y) and the other end switch I have two of these. HVAC Technician: BillyHvac. On a zone valve system you have a separate thermostat thats only job is to open and close zone valves. The thermostats do not connect directly to the boiler. Then you have a transformer in the boiler that sends ...How To Wire a System Circulator to a Zone Valve Control (ZVC) from Taco, Inc.This is easy. Change your V8043A for another V8043F or a V8043E. Wire both end switches together and connect to the boiler where the diagram shows thermostat connection and when either zone calls the boiler starts and turns on the circulator. The transformer you have from the old boiler can operate the zone valve powerheads.1. BOILER CONNECTION: On the old wiring junction from the boiler I have 5 wires coming. 2 wires, black and brown connected to line, blue is in neutral and green goes to earth and then there is a grey which is connected to the honeywell 2 zone valve orange wire.The zone valves should be located on the supply side of the zone circuits to eliminate heat migration into inactive zone circuits. The tee shown below the zone valves is a “bullhead” tee. When both zones are on, return flows slam directly into each other. This creates turbulence and noise. It also wastes circulator head.Honeywell V8043e1012 Motorized Zone Valve Sweat. Dakota Supply Group 24v 3 4 In Npt N C Zone Valve. Need Some Advice On Wiring Boiler Zone Valves Heating Help The Wall. Honeywell Zone Valves Valve Parts Catalog Manualzz. V8044a1044 U. Zone Valve Wiring Manuals Installation Instructions Guide To Heating System Valves Inspection RepairI have been given the task of wiring a hot water boiler with 5 zone valves. the boiler has a low voltage wire comming out of the side of it. The electrician has already wired the 120v but I think he still needs to include the low water cut off after the service switch on the side of the unit.Learn how to fix your hydronic heating by changing the zone valve motor with this easy tutorial. Watch the video and save money on repairs.When the zone valve fully opens and its end switch makes contact, the red LED will come on, the boiler turns on and a circulator will start if connected to the zone control. For information on Taco’s Zone Valve Controls (ZVC) including catalog sheet, instruction sheets, Visio stencils and our highly praised Zone Controls Wiringthe zone valves wiring scheme was already setup over 20 yrs ago and that wasn't touched at all, you are suggesting an entirely different wire plan the transformer did come preinstalled and semi wired inside the new boiler, our issue is that we have 2 sets of tstat wires and the black leads and not sure of proper connections to make it go auto ...Now, for the zone valves to signal the boiler there is a call for heat, you need to wire in terminals 2 and 3 on the valve. Your boiler has "TT" terminals. One "T" is 24VAC and the other is common. Once you know which one is 24VAC (check with a voltmeter), that T attaches to Terminal 3. DO NOT ATTACH 24VAC TO TERMINAL 2.Step 3 - Connect the Wiring to the Zone Valve. The zone valve acts as the relay between the thermostat and the boiler by working in conjunction with a transformer. The transformer converts the 110-volt feed from the panel to a lower voltage that matches the thermostat wiring. Take the cover off the transformer and install the boiler ...How the Taco 571 Zone Valve Explained & How to WireThis is easy. Change your V8043A for another V8043F or a V8043E. Wire both end switches together and connect to the boiler where the diagram shows thermostat connection and when either zone calls the boiler starts and turns on the circulator. The transformer you have from the old boiler can operate the zone valve powerheads.Per the Preferred Piping schematic in the Munchkin manual (see the munchkin PDF attachment-ignore the DHW) I am using a Primary/Secondary pumping setup with two Taco 007's and two Honywell zone valves (4 wire). I am wondering how to wire up my two zone thermostats to control the two zone valves in addition to the two pumps and boiler.I can give you a general idea but as for what the valve controls is up to the install. On a basic Honeywell zone valve there are four leads two yellow and two red. The red are an end switch that makes when the valve is fully open, so if you check them with a continuity tester they will only be made when the valve is driven fully open.Ensure that all wires are properly connected and tightened in the 571 2 zone valve. Use a screwdriver to secure any loose terminals and ensure a solid connection. Loose connections can cause intermittent or complete loss of power, resulting in heating or cooling issues. 2. Verify power supply.Recently, I had a zone valve go out in my hydronic, boiler based heating system. I had to figure out how the system works so I could get it replaced. I don...Weil McLain and zone valves. kevsul1 Member Posts: 28. November 2021. I have a Weil McLain cga-5-pidn that I’m switching the three zone valves to taco 3 wire. The boiler has 2 wires labeled “stat” and 2 wires labeled “R” & “C”coming off the controller inside can tge “stat” wires be used as my TT wires for the zone valve end ...Feb 24, 2010 · Step 3 – Connect the Wiring to the Zone Valve. The zone valve acts as the relay between the thermostat and the boiler by working in conjunction with a transformer. The transformer converts the 110-volt feed from the panel to a lower voltage that matches the thermostat wiring. Take the cover off the transformer and install the boiler ... Page 3 If the boiler manufacturer recommends a wiring diagram, follow his instructions. If none are available, the following diagrams show suggested circuits for Type 1311 Water Valves in conjunc- tion with other W-R controls. A 40 VA transformer will handle up to four (4) water valves. A 20 VA transformer will handle up to two (2) water valves.Boiler zone valve. Zone valves find applications in domestic hot water storage tanks. These valves help direct hot water from the boiler to different places like radiators and the domestic hot water storage tank. ... Check the power supply, wiring, and the root cause of the motor burnout before replacing the motor. Leaking or stuck …Steam has mainly been a gaming marketplace for PC games over the years, but Valve appears to be doubling down on the platform’s social aspects with its newly launched Steam Chat me...Water continues to flow through the boiler water jacket to a drain until the boiler cools enough for the valve to shut again. Typical Dump Zone Wiring If there is an over-heating event and there is electric power, a temperature based switch, such as an aquastat starts a circulator on a designated heating load/zone of heat.Combination Boiler with Two Heating Zones - Universal. Wiring diagrams for two zone valves with a combination boiler. This can be used with any boiler control voltage including 24V, volt free, 230V and others. The difference is that the zone valve switch is used to connect two terminals in the boiler together, rather than connecting 230V to one ...We include wiring diagrams and installation instructions for most zone valve model and multi-zone controllers, and we describe special wiring problems that can occur if you mix different types, brands, or models of heating zone valves on the same hydronic heating (hot water heating) system.I had so many views on the video I did for "How a Hotwater Natural Gas Boiler Works" that I thought I would do a second video around the the zone valve in a ...The control unit is basically a relay operated by the thermostat that 1) fires the boiler and 2) turns a circulating pump on and off. While the boiler and pump are on separate feeds coming out of the control unit, they are switched simultaneously so the pump operates only when the boiler is fired.We include wiring diagrams and installation instructions for most zone valve model and multi-zone controllers, and we describe special wiring problems that can …• For two-way valves: Clockwise to close and Counterclockwise to open. • For three-way valves: Clockwise to increase AB to B (common) flow and counterclockwise to increase A to B (common) flow. 6. The valve must be mounted with the actuator/bracket above the valve body. Do not install the valve with the stem below horizontally or upside down. Fluid Temperature Range: 50 F to 200 F. Electrical Connections: 18" leads. Power Consumption: 7.7 VA. Nominal Timing: 15 sec. Valve Action: Spring return to close. Dimensions: 4" high x 3-1/2" wide x 2-3/8" deep. Auxiliary End Switch: SPST. End Switch Rating: 50 VA pilot duty @ 24 V. Static Pressure (psi): 125 psi. Install wiring and electrically ground boiler in accordance with requirements of the authority having jurisdiction, or in absence of such requirements the National Electrical Code, ANSI/NFPA 70, and/or the CSA C22.1 Electric Code.Explore the different types of shower valves and controls for your bathroom. Find the perfect one that suits your needs and preferences. Shop now! Expert Advice On Improving Your H...Apr 22, 2020 ... Deep Dive Switching Relays and Zone Valve Controllers · Honeywell Basic Hydronic Control Training · Hydronics System Components · How to Wire&...How To Wire a System Circulator to a Zone Valve Control (ZVC) from Taco, Inc.Zone 2 active. The wires highlighted in red are connected to 230V when zone 2 is active. The thermostat contact closes, which connects 230V to the output terminal 3. This is connected in the wiring centre terminal 8 to the zone valve, the valve motor opens the valve and a switch inside connects grey and orange together.TWO PORT ZONE VALVE. How motorised valves work in plumbing systems. Central heating motorised valve how do they work. How does an s plan central heating syst...The 3 and 4 terminals are looking for a zone valve end-switch closure to close the main end-switch which is typically interfaced with the boiler thermostat terminals. If you use a two wire zone valve without an end-switch we need to simulate an end switch closure by placing the shunt across the 3, and 4 end-switch terminals.The zone valves should be located on the supply side of the zone circuits to eliminate heat migration into inactive zone circuits. The tee shown below the zone valves is a "bullhead" tee. When both zones are on, return flows slam directly into each other. This creates turbulence and noise. It also wastes circulator head.Steam has mainly been a gaming marketplace for PC games over the years, but Valve appears to be doubling down on the platform’s social aspects with its newly launched Steam Chat me...Step 5 - Removing the Zone Valve. The zone valve will be bolted onto the pipe. When it's safe to do so, the zone valve can simply be unbolted and removed from the line of pipe. Be careful when doing this because the valve can stay hot for some time, even when the boiler is shut off. Use the screwdriver to remove the electrical connections from ...The C wire should not connect to the W wire, it's a 3rd terminal. Oct 29, 2014 at 22:48. @MikeN: I agree with Mazura's latest comments, it looks like the C terminal is not visible in your photos (and possibly isn't accessible at all). Tester101 has a great answer about what the C wire is and where it attaches, which may be helpful in locating ...Zone Pump - Zone Valve Boilers & Combi Boilers - NAVIENAvailable online at: https://thefurnaceoutlet.com/UNDERFLOOR HEATING - How To Wire - Wet underfloor heating system. How to wire. Central heating design. In-Floor Radiant HeatBeneath Heat This video is just f...L3 - RED-HIGH WATER TEMPERATURE L4 - RED-BLOCKED FLUE L5 - GREEN-BURNER ON L6 - RED-BLOCKED DRAIN L7 - AMBER-LOW GAS PRESSURE L8 - RED-FLAME FAILURE L9 - RED-LOW AIR PRESSURE L10 - CLEAR-PRE-PURGE. #1 THROUGH #12 ARE CONNECTED ON IGNITION MODULE. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED ...All about 2 Port Valves central heating and Wiring! I'll show you how easy they are to wire on a heating system by ignoring the neutral and earth wires until...This is the most common method HVAC Pros use when wiring Honeywell zone valves.Product Features. Use with AQ1000 two-wire communicating thermostats, or most dry contact digital thermostats, Offers zoning control for up to four zones and controls up to two stages of heat from a single thermostat, Can expand up to 16 zones with AQ255 or AQ257 or up to 64 zones with AQ254 Add-A-Temp panels, Line or low-voltage output for ...1361 103 Emerson White Rodgers 1 Sweat 2 Way Normally Closed Zone Valve Amre Supply. Zone Valve Wiring Manuals Installation Instructions Guide To Heating System Valves Inspection Repair. Packaged Gas Electric Unit 3 5 Ton Belt Drive Ultra Low Nox Light Commercial Dbg Models Installation Instructions. 1361 103 Emerson White Rodgers 1 Sweat 2 Way ...TrueZONE HZ322 with Hot Water Zone Valve or Circulator Relay Panel Hot Water Zone Valves with A/C Dampers There are different ways to wire zone valves to the aquastat. AFor complete wiring instructions on any of the zone valve and aquastat refer to the product data sheets for those controls. M1 M4 M6 R C W Y G M1 M4 M6 R C W Y G M1 M4 M 6 R C W ...LWCI Wiring Centre Hub" Boiler • 230V a.c. Cyl. Thermostat C 12 HTS3 Motorised Valve Pump g 10 M Mains Input Mains Function Leads VALVE CH VALVE live the d is used is to terminal sale Model WT724R, WV724R C y.. Thermostat IS 12 g 11 Pump 12 13 15 16 Links made by Mains Input Mains Boiler Motorised ZA6 CH ZONE 2 5 N E 6 is Hw CIRCUIT VALVE CH ZONEOn controls. In general, the thermostats will control the zone valves or pumps. They in turn -- either directly or through the Taco -- will control the boiler either directly or indirectly with the boiler having its own controls, such as an aquastat. Each application tends to be somewhat different, although there are some general principles.1 Answer. One of those transformer terminals is "R" the other is "C". If the red wire joins to the thermostat "R" wires then the beige wire is "C". Thermostat wires should not be inside that junction box with the mains wiring, get a new box for the thermostat wires. After looking at pictures I posted I can now see one of the terminals on the ...This is the most common method HVAC Pros use when wiring Honeywell zone valves.In this video I will show you how to wire this beautiful lux thermostat to your 1311 white Rodgers zone valve1361 103 Emerson White Rodgers 1 Sweat 2 Way Normally Closed Zone Valve Amre Supply. Zone Valve Wiring Manuals Installation Instructions Guide To Heating System Valves Inspection Repair. Packaged Gas Electric Unit 3 5 Ton Belt Drive Ultra Low Nox Light Commercial Dbg Models Installation Instructions. 1361 103 Emerson White …This is how a Zone Control System for a Boiler Works, what the functions are, how to wire it, and what the signal voltages and relays do!Tool List- https://...The ONLY video on the internet that shows you how.Nest Power Connector: https://amzn.to/3hy1l2PNOTE: A separate power connector is required for EACH Nest The...the zone valves wiring scheme was already setup over 20 yrs ago and that wasn't touched at all, you are suggesting an entirely different wire plan the transformer did come preinstalled and semi wired inside the new boiler, our issue is that we have 2 sets of tstat wires and the black leads and not sure of proper connections to make it go auto ...I had so many views on the video I did for "How a Hotwater Natural Gas Boiler Works" that I thought I would do a second video around the the zone valve in a ...I've also seen some thermostats come with instructions for hooking up a second plug-in transformer to power the thermostat without needing to mess with the furnace/boiler wiring. - JPhi1618. Nov 3, 2017 at 18:19. The "C" marking on a furnace controller is generally the "common" lead from the 24vac transformer, using a black wire.Oct 22, 2022 · Learn how to quickly wire in multiple zone valves on a boiler. Includes 5 Step Cheat Sheet:https://i.postimg.cc/wxbyRtMV/Zone-Valve-Cheat-Sheet.pngFlow Path ... Hover Image to Zoom. $ 42 60. Pay $17.60 after $25 OFF your total qualifying purchase upon opening a new card. Apply for a Home Depot Consumer Card. Perfectly fits the Honeywell 24 V zone valve. Motor mounting screw and lead connectors included. Included components help in easy installation. View More Details.Hot Water Boiler Piping Zone Valves Wiring Diagram Quality 1. Dakota Supply Group 24v 3 4 In Npt N C Zone Valve. Honeywell Motorised Valve Clearance 50 Off Www Ingeniovirtual Com. Control A 3 Wire Zone Valve With 2 Thermostat Geek Wisdom Com. China 2 Port Motorized Zone Valve 5 Wire Replaces Honeywell V4043h Photos …Boilers - Home Heating Steam and Hot Water Systems - No zone valves on my system - I have oil heat with 3 zones/3 thermostats (basement, 1st/2nd floor) using baseboards. The 3 thermostats are 110v line voltage units that operate the 3 circulator pumps. There are no zone valves on this system. I would like to install 3 Three wire zone valve wiring is a common method used in heating systems to control the flow of hot water. The wiring consists of three wires, which are connected to a thermostat, the zone valve, and the boiler. The first wire is connected to the thermostat, which senses the room temperature and sends a signal to the zone valve to open or close. This HVAC Training Video goes over the High-Efficiency Taco Sentry Zone Valve. I go over installation practices, head removal, wiring, amp draw, connection t...Purge air from a boiler with a Purge & Fill Ball Valve. Webstone Brand - 1 Inch H-58614 - https://amzn.to/3TUIX4IOther sizes - https://amzn.to/3TWlrnR

Zone Valve Wiring Explained For Beginners (Honeywell) Clear explanation and diagram overview on how a 4-wire zone valve works and how it is wired into a boiler low voltage …. Middletown ct car accident yesterday

how to wire a zone valve on a boiler

The installation and user manual for each combi-boiler models includes multiple installation diagrams for various applications including: Zone systems with pumps. Zone systems with zone valves. Air handler systems. Air handler systems with RS-485 communication. External recirculation mode with dedicated return line.Hover Image to Zoom. $ 42 60. Pay $17.60 after $25 OFF your total qualifying purchase upon opening a new card. Apply for a Home Depot Consumer Card. Perfectly fits the Honeywell 24 V zone valve. Motor mounting screw and lead connectors included. Included components help in easy installation. View More Details.Apr 2, 2018 · In this video I show you how to change the mechanical plumbing part of the valve. In a previous video I showed how to change the motor of a zone valve. The... In this video I will show you step by step how to replace Honeywell zone valve motor, power head , and ball valve.https://www.supplyhouse.com/Honeywell-Zone-...The Chevrolet 5.7-liter (350-cubic-inch) engine employs an overhead valve design that requires occasional maintenance. Adjusting the clearance between the valve stem and rocker arm...On 2019-09-12 by (mod) -. Spencer. 2 common causes for a zone valve refusing to open unless another zone is active are. 1. Zone valve is not wired correctly. 2. Zone valve is controlling a subordinate Zone that is actually fed off of one of the other zones' hot water line.Taco zone valve wiring. My house has 6 zones coming off the boiler . 5 of then are for the heating zones (only use 4, 1 need comes on because it's the second floor, and 1 is for a stand alone heater in the garage that I removed the thermostat) and 1 zone connects to the indirect water heater . The 24 volt power to all these heads is wired on ...The V8043 Motorized Zone Valve provides two-position (open-close) control of supply water for baseboard radiation, convectors, fan-coil units, etc. It uses a two-wire, 24-volt con­ trol circuit and requires a SPST thermostat. Integral end-switch models permit the sequencing of auxiliary equipment. Quick Fit actuator provides easy snap on and ...Turn power off to boiler. Disconnect the zone valve endswitch wires from the R and G terminals in the boiler. Place a wire JUMPER between the R and G terminals and turn power to boiler back on. Circ pump should run and boiler should fire. If not, then something going on with boiler.Oct 22, 2022 · Learn how to quickly wire in multiple zone valves on a boiler. Includes 5 Step Cheat Sheet:https://i.postimg.cc/wxbyRtMV/Zone-Valve-Cheat-Sheet.pngFlow Path ... Do you want to learn how to wire your boiler thermostat correctly and safely? Watch this video tutorial from a professional electrician who explains the steps and tips for wiring different types ...4 Wire, 5 Wire Honeywell Zone Valve Wiring, Troubleshooting. Check Details. Hot water boiler piping zone valves and wiring diagrams.. L8148 Aquastat Installation, Wiring & Set-up L8148 & Manuals Honeywell. Check Details. I just purchased a replacement for a Honeywell 40004850-001 zone valve. Check Details. Hot Water Boiler Piping Zone Valves ...You will need to wire the combination boiler first to a zone valve controller and then that will send a signal to the combi boiler to turn on the boiler. Ask Your Own ….